Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.

Detalles CVE

Puntuacion CVSS v3.1N/A
Publicado6/26/2018
Ultima modificacion11/21/2024
Fuentenvd
Avistamientos honeypot0

Productos afectados

deltaww:commgrdeltaww:dvpsimulator_ahsim_5x0deltaww:dvpsimulator_ahsim_5x1deltaww:dvpsimulator_eh2deltaww:dvpsimulator_es2deltaww:dvpsimulator_h3deltaww:dvpsimulator_sedeltaww:dvpsimulator_ss2