← Volver a CVEs
CVE-2018-10694
HIGH8.1
Descripcion
An issue was discovered on Moxa AWK-3121 1.14 devices. The device provides a Wi-Fi connection that is open and does not use any encryption mechanism by default. An administrator who uses the open wireless connection to set up the device can allow an attacker to sniff the traffic passing between the user's computer and the device. This can allow an attacker to steal the credentials passing over the HTTP connection as well as TELNET traffic. Also an attacker can MITM the response and infect a user's computer very easily as well.
Detalles CVE
Puntuacion CVSS v3.18.1
SeveridadHIGH
Vector CVSSCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Vector de ataqueNETWORK
ComplejidadHIGH
Privilegios requeridosNONE
Interaccion usuarioNONE
Publicado6/7/2019
Ultima modificacion11/21/2024
Fuentenvd
Avistamientos honeypot0
Productos afectados
moxa:awk-3121moxa:awk-3121_firmware
Debilidades (CWE)
CWE-311
Referencias
http://packetstormsecurity.com/files/153223/Moxa-AWK-3121-1.14-Information-Disclosure-Command-Execution.html(cve@mitre.org)
https://seclists.org/bugtraq/2019/Jun/8(cve@mitre.org)
http://packetstormsecurity.com/files/153223/Moxa-AWK-3121-1.14-Information-Disclosure-Command-Execution.html(af854a3a-2127-422b-91ae-364da2661108)
https://github.com/samuelhuntley/Moxa_AWK_1121/blob/master/Moxa_AWK_1121(af854a3a-2127-422b-91ae-364da2661108)
https://seclists.org/bugtraq/2019/Jun/8(af854a3a-2127-422b-91ae-364da2661108)
Correlaciones IOC
Sin correlaciones registradas